The Journal of General Physiology
Avanti Polar Lipids, Inc.
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

This Article
Right arrow Full Text (PDF, 1136K)
Right arrow Alert me when this article is cited
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Alert me to new content in the JGP
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sollner, K.
Right arrow Articles by Abrams, I.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Sollner, K.
Right arrow Articles by Abrams, I.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
The Journal of General Physiology, Vol 25, 411-429, Copyright © 1942 by The Rockefeller University Press


ARTICLE

THE STRUCTURE OF THE COLLODION MEMBRANE AND ITS ELECTRICAL BEHAVIOR

III. THE BASE EXCHANGE PROPERTIES OF COLLODION



Karl Sollner 1, Charles W. Carr 1, and Irving Abrams 1

1 From the Department of Physiology, University of Minnesota, Minneapolis

1. Theoretical considerations lead to the conclusion that dissociable acidic groups present to a varying extent in different collodion preparations determine the electrochemical behavior of membranes cast from these preparations. It is further reasoned that the base exchange capacity of the collodion surfaces is the true quantitative measure of the abundance of the dissociable groups.

2. The concept of base exchange capacity and the base exchange method are discussed. The conditions which allow a purposeful application of the latter are stated.

3. The base exchange properties of a number of fibrous collodion preparations of different origins and after various types of treatment, having widely varying electrochemical activities, are determined.

4. With the chemical (titration) and physical (electrometric) methods employed, no regular correlation can be found between electrochemical activity and base exchange. The base exchange capacity which is necessary to cause even great electrochemical activity of collodion is extremely small.

5. Measurable to high base exchange capacity always seems to be associated with good or high electrochemical activity; but base exchange capacity too low to be definitely measurable with the available methods may be found with collodion preparations of high as well as with preparations of low electrochemical activity.

6. The bearing of these results upon the problem of the spatial and electrical structure of the collodion membrane is indicated briefly.

Submitted on October 18, 1941