The Journal of General Physiology
Axon Instruments microelectrode amplifiers
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

This Article
Right arrow PDF (Full Text)
Right arrow Alert me when this article is cited
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new content in the JGP
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brown, H. M.
Right arrow Articles by Saunders, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brown, H. M.
Right arrow Articles by Saunders, J. H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

The Journal of General Physiology, Vol 70, 531-543, Copyright © 1977 by The Rockefeller University Press


ARTICLES

Cation and anion sequences in dark-adapted Balanus photoreceptor

HM Brown and JH Saunders

Anion and cation permeabilities in dark-adapted Balanus photoreceptors were determined by comparing changes in the membrane potential in response to replacement of the dominant anion (Cl-) or cation (Na+) by test anions or cations in the superfusing solution. The anion permeability sequence obtained was PI greater than PSO4 greater than PBr greater than PCl greater than Pisethionate greater than Pmethanesulfonate. Gluconate, glucuronate, and glutamate generally appeared more permeable and propionate less permeable than Cl-. The alkali-metal cation permeability sequence obtained was PK greater than PRb greater than PCx greater than PNa approximately PLi. This corresponds to Eisenman's IV which is the same sequencethat has been obtained for other classes of nerve cells in the resting state. The values obtained for the permeability ratios of the alkali-metal cations are considered to be minimal. The membrane conductance measured by passing inward current pulses in the different test cations followed the sequence, GK greater than GRb greater than GCs greater than GNa greater than GLi. The conductance ratios obtained for a full substitution of the test cation agreed quite well with permeability ratios for all the alkali-metal cations except K+ which was generally higher.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?




  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents