The Journal of General Physiology
Axon Instruments microelectrode amplifiers
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

This Article
Right arrow Full Text (PDF, 1383K)
Right arrow Alert me when this article is cited
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new content in the JGP
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Livengood, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Livengood, D. R.
Right arrowPubmed/NCBI databases
*Compound via MeSH
*Substance via MeSH
Hazardous Substances DB
*POTASSIUM
*SODIUM
*SODIUM CHLORIDE
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

The Journal of General Physiology, Vol 82, 853-874, Copyright © 1983 by The Rockefeller University Press


ARTICLES

Coupling ratio of the Na-K pump in the lobster cardiac ganglion

DR Livengood

The electrogenic Na-K pump coupling ratio in the large neurons of the lobster cardiac ganglion was determined by two different electrophysiological techniques. A graphical analysis plotting exp(EmF/RT) vs. [K]o after the pump was blocked by ouabain was used to determine values for [K]i, PNa/PK, and the pump coupling ratio. These measurements were made 4-8 h after the cells were penetrated with microelectrodes, and thus represent non-Na-loaded steady state values. The value obtained for the pump coupling ratio under these conditions was 1.44 +/- 0.06 (n = 9) or close to 3 Na for 2 K. The second technique used to measure the coupling ratio was to iontophoretically inject Na ions into the neuron. Neurons were penetrated with three microelectrodes, two of which were filled with 2 M Na-citrate; the third electrode contained either 2 M K-citrate or 3 M KCl. By passing current between the Na salt-containing electrodes, Na was injected into the cell soma. The injection system was calibrated by injecting 24Na- citrate into counting vials from representative microelectrodes (calculated 24Na transport = 0.92). By knowing the Na load injected into the cells, and by measuring the time-current area produced by the Na activation of the Na-K pump, the coupling ratio was calculated to be 1.54 +/- 0.05 (n = 19), which is not significantly different from the value obtained by the first method. This value represents a Na-loaded experimental situation. When Na was removed from the external bathing solution, the coupling ratio shifted to 2 Na to 1 K (2.0 +/- 0.07, n = 4). These results suggest that the pump normally operates with a 3:2 ratio both in steady state and under Na load but that in the absence of external Na, it can operate with less than a full complement (2) of K on the external surface of the pump.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Biol. Bull.Home page
I. M. Cooke
Reliable, Responsive Pacemaking and Pattern Generation With Minimal Cell Numbers: the Crustacean Cardiac Ganglion
Biol. Bull., April 1, 2002; 202(2): 108 - 136.
[Abstract] [Full Text] [PDF]



  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents